summaryrefslogtreecommitdiff
path: root/altoslib/AltosUnknownProduct.java
Commit message (Collapse)AuthorAge
* altoslib,altosuilib: Bump library version numbersKeith Packard2017-06-13
| | | | | | The API and ABI have changed a bit since 1.7 Signed-off-by: Keith Packard <keithp@keithp.com>
* Switch from GPLv2 to GPLv2+Keith Packard2016-07-12
| | | | Signed-off-by: Keith Packard <keithp@keithp.com>
* Bump java library versionsKeith Packard2016-05-12
| | | | | | Prepare for 1.6.4 release Signed-off-by: Keith Packard <keithp@keithp.com>
* altoslib: Deal with TeleMetrum v2.0 MMA6555 being invertedKeith Packard2016-05-02
Dumping the MMA655X data with the 'A' command provides the raw sensor value. On TM v2.0 boards, the sensor is inverted, and all of the firmware uses the inverted value except for the 'dump the raw data' command. As a result, MonitorIdle was using the un-inverted value and displaying mystic values. I've fixed this in the ground station code by checking the product name and conditionally inverting the value (4095 - value) for TeleMetrum v2.0 products. Unknown products will generate a warning dialog on AltosUI so we'll catch places where we've failed to add a new product name. Signed-off-by: Keith Packard <keithp@keithp.com>